Bend Test |
grade |
tensile strength,min |
yield strength, 0.2% offset |
elongation
In 2 in. or
50 mm,
Min, % |
under
0.070 in
(1.8 mm) in
Thickness |
0.070 to
0.187 in.
(1.8 to 4.75
Mm) in
Thickness |
min |
max |
ksi |
mpa |
ksi |
mpa |
ksi |
mpa |
1 |
35 |
240 |
20 |
138 |
45 |
310 |
24 |
1.5t |
2t |
2 |
50 |
345 |
40 |
275 |
65 |
450 |
20 |
2t |
2.5t |
2h |
58 |
400 |
40 |
275 |
65 |
450 |
20 |
2t |
2t |
3 |
65 |
450 |
55 |
380 |
80 |
550 |
18 |
2t |
2.5t |
4 |
80 |
550 |
70 |
483 |
95 |
655 |
15 |
2.5t |
3t |
5 |
130 |
895 |
120 |
828 |
… |
… |
10vii |
4.5t |
5t |
6 |
120 |
828 |
115 |
793 |
… |
… |
10vii |
4t |
4.5t |
7 |
50 |
345 |
40 |
275 |
65 |
450 |
20 |
2t |
2.5t |
7h |
58 |
400 |
40 |
275 |
65 |
450 |
20 |
2t |
2t |
9 |
90 |
620 |
70 |
483 |
… |
… |
15viii |
2.5t |
3t |
11 |
35 |
240 |
20 |
138 |
45 |
310 |
24 |
1.5t |
2t |
12 |
70 |
483 |
50 |
345 |
… |
… |
18 |
2t |
2.5t |
13 |
40 |
275 |
25 |
170 |
… |
… |
24 |
1.5t |
2t |
14 |
60 |
410 |
40 |
275 |
… |
… |
20 |
2t |
2.5t |
15 |
70 |
483 |
55 |
380 |
… |
… |
18 |
2t |
2.5t |
16 |
50 |
345 |
40 |
275 |
65 |
450 |
20 |
2t |
2.5t |
16h |
58 |
400 |
40 |
275 |
65 |
450 |
20 |
2t |
2t |
17 |
35 |
240 |
25 |
170 |
45 |
310 |
24 |
1.5t |
2t |
18 |
90 |
620 |
70 |
483 |
… |
… |
15viii |
2.5t |
3t |
19ii |
115 |
793 |
110 |
759 |
… |
… |
15 |
3t |
3t |
20ii |
115 |
793 |
110 |
759 |
… |
… |
15 |
3t |
3t |
21ii |
115 |
793 |
110 |
759 |
… |
… |
15 |
3t |
3t |
23ii |
120 |
828 |
110 |
759 |
… |
… |
10 |
4.5t |
5t |
24 |
130 |
895 |
120 |
828 |
… |
… |
10 |
4.5t |
5t |
25 |
130 |
895 |
120 |
828 |
… |
… |
10 |
4.5t |
5t |
26 |
50 |
345 |
40 |
275 |
65 |
450 |
20 |
2t |
2.5t |
27 |
35 |
240 |
25 |
170 |
45 |
310 |
24 |
2t |
4t |
28 |
90 |
620 |
70 |
483 |
… |
… |
15 |
2.5t |
3t |
29 |
120 |
828 |
110 |
759 |
… |
… |
10 |
4.5t |
5t |
30 |
50 |
345 |
40 |
275 |
65 |
450 |
20 |
2t |
2.5t |
31 |
65 |
450 |
55 |
380 |
80 |
550 |
18 |
2t |
2.5t |
32 |
100 |
689 |
85 |
586 |
… |
… |
10vii |
3.5t |
4.5t |
33 |
50 |
345 |
40 |
275 |
65 |
450 |
20 |
2t |
2.5t |
34 |
65 |
450 |
55 |
380 |
80 |
550 |
18 |
2t |
2.5t |
35 |
130 |
895 |
120 |
828 |
|
|
5 |
8t |
8t |
36 |
65 |
450 |
60 |
410 |
95 |
655 |
10 |
4.5t |
5t |
37 |
50 |
345 |
31 |
215 |
65 |
450 |
20 |
2t |
2.5t |
38 |
130 |
895 |
115 |
794 |
|
|
10 |
4t |
4.5t |
above
Mechanical limits apply to tests taken both longitudinal and
Transverse to the direction of rolling. Mechanical
Properties for conditions other than annealed or plate thickness
Over 1 inch may be established by agreement between the
Manufacturer and the purchaser.”T” equals the
Thickness of the bend test specimen. Bend tests are not
Applicable to material over 0.187 in (4.75 min) in thickness. |
ii)
Properties for solution treated condition. Material is most
Often purchased and supplied in the solution treated condition.
Aged material may be available, but is subject to negotiation
Between purchaser and supplier. |
vii)
Elongation for grades 5, 6 and 32 on materials under 0.025 inch
In thickness subject to negotiation manufacturer and purchaser. |
viii)
Elongation for continuous rolled and annealed (strip product
From coil) for grade 9 and grade 18 shall be 12% minimum in the
Longitudinal direction and 8% minimum in the transverse
Direction. |
** While this information has
been compiled with care, it is for convenience and for reference
only and we assume no liability for any decisions based on the
content therein. it shall be your responsibility to ensure
that any information in this document or on our website meets your